Coroguard SBP 100 : Coal Tar Epoxy  

 

Product Description :

 

Coroguard SBP - 100 is high solids, high build polyamide cured coal tar epoxy coating. The outstanding water resistance of coal tar, together with the chemical and solvent resistance, toughness and adhesion of epoxy resin, combine to give excellent overall corrosion protection.

 
Features and Benefits :
 

Easy to apply and can be applied via airless spray, conventional spray, brush or roller.

Can be used as primer, intermediate or finish coat.

Suitable for varied end application i.e. ideal for heavy industrial, chemical, marine, splash and spillage, fresh water, sea water or chemical immersion.

Provides desired film build up to 125 microns per coat.

Excellent resistance to acids, alkalis, water, salts, oils, petroleum solvents.

Has excellent impermeability to water and chemical vapours.

Has excellent adhesion property over a steel and concrete when applied without primer. 

Tough hard film that serves as single protective coat in severe corrosive conditions. (Topcoats are recommended for maximum protection.)

Provides long-term protection and is economical.

 

   
 

Recommended uses :

 
 

 

 
 

Steel structure

Off-shore Platforms

Petroleum Refinerie

Sewage Equipments

Concrete surfaces

Pulp & Paper Mills

Silos & hoppers in Cement Industry

Non-potable water tank

Pipelines

Dam Gates

Tidal & Splash Zones

Underground Tanks

Water-proofing on Concrete Structures Canal Linings

Shipbuilding Industry

Wineries

 
     
 

Resistance Guide :

 
     
 

Immersion @ 30° C

---Fresh water, salt water, gasoline, dilute alkalis, aliphatic solvents.

(Resistance to spillage and splash - not immersion)

Aliphatic solvents, gasoline, kerosene, fuel oil : Severe
Alkalis : Severe
Aromatic Solvents : Limited
Oxygenated Solvents : Limited 
Weak solutions of mineral & organic acids : Moderate
Fats & oils, lubricating oils, cutting oils : Moderate
 
     
  Surface Preparation :  
     
 

SteelThe surface should be blast cleaned to SSPC-SP 10-63T or NACE No. 2 i.e. loose rust and scales, dirt, grease, oil, paint, wax, weak oxide films and other contaminants should be removed. Blast cleaning to SSPC-SP 5-63 or NACE No. 1 is recommended where heavy corrosive conditions exist or coating is required to be immersed. That means a surface with a grey metallic colour, slightly roughened to form a suitable anchor pattern for coatings. This surface is free of all oil, grease, dirt, mill scale, rust, corrosion products, oxides, paint and other foreign matter. In absence of blast cleaning, prepare the metal surface by wire brushing, sanding, grinding, scrapping or chipping with hand or power tools. Remove all the contaminants. Apply two coats of Coroguard SBP - 100. It can be overcoated with Durapoxy 200 Epoxy Enamel, Anuthane Enamel Polyurethane or Monocoat Enamel Polyurethane.

Non-ferrous Metals - Remove dirt, dust, oil, old paint etc. Degrease the surface with degreasing solvents like xylene or tri-chloroethylene. Apply one coat of Anuprime – 291 Wash Primer for obtaining maximum adhesion. Apply one or two coats of Coroguard SBP - 100.

ConcreteThe concrete surfaces must be thoroughly cleaned and free from pits, pockets and holes. Etch the surface with 10-15% muriatic acid diluted in water. Allow the acid solution to remain on the surface for 10 to 15 minutes or until the bubbling stops. Thoroughly rinse the surface to remove all traces of acid. Allow the surface to dry completely before painting.

 
     
 

TECHNICAL DATA

 
     
 

Name/Description

Coroguard SBP - 100

Type

Two pack cold cured

Composition

Epoxy Polyamide / Coal Tar

Colour

Black

Finish

Smooth and Semi - Glossy

Volume Solids (mixed)

75± 3%

Mixing Ratio

Base : Hardener

4 : 1 by volume

Pot Life @ 30° C

6 to 8 hours

Dry film thickness per coat

100 to 125 microns

Coverage-(theoretical-no loss)

7.5 to 6 m² /litre

Serviceability @ 30° C

Dry to touch

Hard Dry

Recoat

Full Cure

 

6 to 8 hours

Overnight

24 hours

7 days

Induction (Sweat-in-time) @ 30° C

30 minutes

Dry heat resistance

120° C

Relative Humidity

90%

Application Temperature

-minimum

-maximum

 

10° C

35° C

Solvent/Thinner

Anusol - ETP Thinner

Flash Point

23° C

Packing

4 & 20 litres

Shelf Life

6 months

Precaution

Flammable. Keep away from heat and open flame. Maintain good ventilation and avoid breathing vapours.

 
     
 
Notes :-  
 
     
 
Brushes and spray equipments should be cleaned with Anusol - ETP Epoxy Thinner.
The contents should be stirred thoroughly prior to use.

After mixing Base and Hardener in recommended proportions, allow for 30 minutes induction period or sweat-in-time (maturing) before application.

When overcoating the weathered or aged Coroguard SBP - 100 ensure that the coating is fully free from all contamination such as oil, dust, grease, stains etc.

This coating should always be thinned with Anusol - ETP Epoxy Thinner. The use of alternative thinners can severely inhibit the curing mechanism of the coating.
 
     
 

Disclaimer :-

 

Information provided herein is based upon tests believed to be reliable. It does not guarantee the results to be obtained. Nor does it make any express and implied warranty or merchantability, or fitness for a particular purpose concerning the effects or results of such case. It does not release you from the obligation to test the products supplied by us as to their suitability for the intended uses. The application, surface preparation and use of the products are beyond our control and, therefore, entirely your own responsibility.

 
     
 