SolutionsPower & Cement
⚡
Power Plant & Cement Plant Coating Systems
High Temperature & Chemical Resistance
Total DFT
250-500 microns (ambient temp areas)
Service Life
15-20 years
Environment
CX (Extreme — high temp, chemical, abrasive dust)
Layers
4 coat system
Coating systems for power generation and cement manufacturing facilities. Includes high-temperature coatings for stacks and boilers, chemical-resistant systems for FGD units, and general structural steel protection.
Coating System — Layer by Layer
1
Primer (ambient)Self-curing IZS
Inorganic Zinc Silicate Primer
Cathodic protection — heat resistant up to 400C
DFT: 60-75 microns
Coats: 1
Airless spray
2
IntermediateEpoxy MIO
Epoxy MIO
Barrier protection
DFT: 100-150 microns
Coats: 1
Airless spray
3
TopcoatAliphatic PU
Aliphatic PU Topcoat
UV stable finish
DFT: 50 microns
Coats: 1
Airless spray
4
High Temp AreasSilicone aluminium
Heat Resistant Aluminium Paint (600C)
For stacks, boilers, exhaust ducts up to 600C continuous
DFT: 25-40 microns
Coats: 2
Spray
Surface Preparation
- Blast cleaning to Sa 2.5
- Surface profile as per product specification
Applicable Standards
ISO 12944ASTM C411IS 15155
Applications
- Thermal power plants
- Cement plant structures
- Boiler casings
- Exhaust stacks and chimneys
- Coal handling plants
- ESP structures
- Cooling towers
Why Anupam Paints
- Heat resistant up to 600C
- Supplied to BHEL, NTPC facilities
- Complete range from ambient to high-temp
- Abrasion resistant for dusty environments
Need This Coating System?